Part Number Hot Search : 
ARJ2012X X4003M8I ARJ2012X 1608S NZH3V3A RN2414 2SB14 HC144T
Product Description
Full Text Search
 

To Download DMF-50840-SFW Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 First Edition
Approved by
Production Div.
Mar 30, 1999
Checked by
Quality Assurance Div.
LCD Module Specification
Final Revision Checked by Design Engineering Div.
*******
Prepared by Type No. Production Div.
Table of Contents
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. General Specifications .............................................................................2 Electrical Specifications...........................................................................3 Optical Specifications ..............................................................................8 I/O Terminal...........................................................................................10 Test..........................................................................................................12 Appearance Standards............................................................................13 Code System of Production Lot ..........................................................16 Type Number..........................................................................................16 Applying Precautions .............................................................................16 Precautions Relating Product Handling................................................17 Warranty..................................................................................................18
Revision History
Rev. Date Page Comment
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 1/18
1.General Specif ications
Operating Temp. Storage Temp. Dot Pixels Dot Size Dot Pitch Viewing Area Outline Dimensions
min. 0 max. 50 min. -20 max. 60 320 (W) x 240 (H) dots 0.33 (W) x 0.33 (H) mm 0.36 (W) x 0.36 (H) mm 120.0 (W) x 90.0 (H) mm 167.1 (W) x 109.0* (H) x 11.0 max.** (D) mm * Without Connector ** Without CFL Cable 230g max. NSD-15885 ( F-STN / Black &White-mode / Transflective ) 9:00 4-bit parallel data transfer Cold Cathode Fluorescent Lamp (CFL) x 1 Dimensional Outline UE-300149
Weight LCD Type
Viewing Angle Data Transfer Backlight Drawings
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 2/18
2.Electrical Specif ications
2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) Input Voltage VI -0.3 VCC+0.3 V VCC-VEE 0 35.0 V Symbol VCC-VSS Conditions Min. -0.3 Max. 7.0 Units V
2.2.DC Characteristics Ta=25, VSS=0V Parameter Supply Voltage (Logic) VCC-VEE Supply Voltage (LCD Drive) VCC-VADJ Shown in 3.1 V 27.0 30.0 V Symbol VCC-VSS Conditions Min. 4.5 Typ. Max. 5.5 Units V
High Level Input Voltage Low Level Input Voltage
VIH
VCC=5.0V10%
0.8xVCC
VCC
V
VIL
VCC=5.0V10%
0
0.2xVCC
V
ICC Supply Current IEE
VCC-VSS=5.0V
5.5
15.0
mA
VCC-VADJ=
V
4.5
10.0
mA
Frame
fF
Duty=50%
70
75
80
Hz
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 3/18
2.3.AC Characteristics VCC=5.0V10% Parameter CP Frequency Clock Pulse Width Load Pulse Width Data Setup Time Data Hold Time Clock Pulse Setup Time Clock Pulse Hold Time Rise/Fall Time FLM Setup Time Symbol Min. 50 63 30 30 80 110 100 Max. 6.0 Note 1 Units MHz ns ns ns ns ns ns ns ns ns
fCP
tWC tWL tSETUP tHOLD tCL tLC tr, tf tFDS tFDH
FLM Hold Time 100 Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships (and ). tr, tf 1 2fCP
tWC
tr, tf 50 ns
LOAD
tr
tWL tCL
tf tLC tWC tWC
CP
tr
tf tSETUP tHOLD
DI 0DI 3
tFDS
FLM
tFDH
This module contain these capacitors. Please be careful about timing characteristics.
FLM
1000pF
LP
470pF
VSS
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 4/18
2.4.Timing Chart
T=0.0556ms typ. LP
CP
D0 D3
SEG 313 316
SEG 317 320
SEG 1 4
SEG 5 8
SEG
SEG 317 320
SEG 1 4
SEG 5 8
#1 DATA
313 316
FLM
LP
(Reduction)
240xT FLM
(Reduction)
2.5.Comparison of Display and Data
SEG1 #1 D3 D2 D1 D0 D1
SEG320 D0
TOP VIEW D0D3
#240
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 5/18
2.6.Power Supply ON/OFF Sequence 2.6.1.ON Sequence
SIGNAL LEVEL VCC VCC
0t
VSS VCC VSS VCC
SIGNAL
0t
VADJ VEE
VSS VADJ VEE
0t
VCC VSS
DISPOFF
2.6.2.OFF Sequence
LEVEL VCC VSS VCC VSS VCC VSS VADJ VEE VCC VSS
0t 0t
SIGNAL
VCC
0t
SIGNAL
VADJ VEE
DISPOFF
Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module.
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 6/18
2.7.Lighting Specifications Ta=25 Parameter Lamp Voltage Lamp Current Starting Voltage Surface Luminance Symbol VL IL VS L Conditions IL=4.0mA Min. 3.0 Typ. 300 4.0 60 Max. 6.0 1000 Units Vrms mArms Vrms cd/ Notes 1 2 3 4
Average Life TAL IL=4.0mA 25000 hrs 5 Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 : Surface Luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the luminance value. Average Life representes the time elapsed at the point of time when the residual ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life mentioned above.
Y=60
Y=160
Y=260
I N V VS VL
C F L
P1 P4 P7
P2 P5 P8
P3 P6 P9
X=60 X=120 X=180
IL
CFL Testing Circuit
Measurement Points
Recommended Inverter :
S-12565 ( Produced by ELEVAM )
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 7/18
3.Optical Specif ications
3.1.LCD Driving Voltage Parameter Recommended LCD Driving Voltage Note 1 : VCC-VEE Symbol Conditions Ta= 0 Ta=25 Min. 22.4 Typ. 24.1 Max. 26.2 25.8 Units V V
Note 1 Ta=50 22.1 V Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range.
3.2.Optical Characteristics Ta=25, 1/240 Duty, 1/14 Bias, VD=24.1V (Note 4), = 0 , = Parameter Contrast Ratio Viewing Angle Response Rise Note 2 TON Note 1 Symbol CR Conditions = 0 , = Min. Typ. 4.5 Max. Units
Shown in 3.3 360 540 ms
Time Decay Note 3 TOFF 340 510 ms Note 1 : Contrast ratio is definded as follows. CR = LOFF / LON LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving Voltage VD VD=VCC-VADJ-VBE Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded as follows. VD = (Vth1+Vth2) / 2 Vth1 : The voltage VO-P that should provide 50% of the satulation level in the luminance at the segment which the ON signal is applied to. Vth2 : The voltage VO-P that should provide 50% of the satulation level in the luminance at the segment which the OFF signal is applied to.
VO-P
( B-2 )xVO-P / B 1 / ( fFxA ) 1 / fF
ON SIGNAL
OFF SIGNAL
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 8/18
3.3.Definition of Viewing Angle and Optimum Viewing Area Point shows the point where contrast ratio is measured. : = 0 , = Driving condition : 1/240 Duty, 1/14 Bias, VD=24.1V, fF=75.0Hz
90 135 45
90
180
10 20 30 40 50
(= 0 180 0
225 270
315 270
Area
shows typ. CR2
3.4.System Block Diagram
Temperature Chamber Rotation Table (,) Photometer #1980A WB LCD Optical Fiber
Computer
Control Unit & Waveform Generator Halogen bulb
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 9/18
4.I/O Terminal
4.1.Pin Assignment CN1 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CN2 No. 5 6 7 8 Symbol FL (HOT) NC NC FL (GND) Level Function Power Supply for CFL (HOT) Non-connection Non-connection Power Supply for CFL (GND) Symbol D0 D1 D2 D3 DISPOFF FLM NC LP CP VCC VSS VEE VADJ FG Level H/L H/L H/L H/L H/L H/L H/L H/L Display Data Display Data Display Data Display Data Display Control Signal H : Display on L : Display off First Line Marker Non-connection Data Latch Signal Clock Signal for Shifting Data Power Supply for Logic Power Supply (0V, GND) Power Supply for LCD Drive Voltage Level for LCD Contrast Adjustment Frame Ground Function
4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence.
VCC R1 VADJ MODULE VEE VR R2
VCC (+Voltage)
VEE (-Voltage)
VSS R1+R2+VR=1020K
VSS (0V)
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 10/18
4.3.Block Diagram
FLM
Row Driver LC79431D x 3 or equivalent
2
240
LCDP 320 x 240 dots
LP DISPOFF
320
2
CP
4
Column Driver LC79401D x 4 or equivalent
D0D3
LP
M Circuit
VCC VSS Bias Circuit To LSI
VADJ VEE
HOT GND
CFL Backlight
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 11/18
5.Test
No change on display and in operation under the following test condition. No. 1 2 3 4 5 6 Parameter High Temperature Operating Low Temperature Operating High Temperature Storage Low Temperature Storage Damp Proof Test Vibration Test Conditions 502, 96hrs (operation state) 02, 96hrs (operation state) 602, 96hrs -202, 96hrs 402, 9095%RH, 96hrs Total fixed amplitude : 1.5mm Vibration Frequency : 1055Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. 3 4 3, 4 3, 4 5 Notes
F E B G D A 60cm Concrete Surface C
Dropping method corner dropping A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once
Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 205 Humidity : 655% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 12/18
6.Appearance Standards
6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45 against perpendicular line.
45
6.2.Definition of applicable Zones
X
X=120.0mm Y=90.0mm
A Zone B Zone C Zone C Zone Bezel Flame
A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 13/18
6.3.Standards No. 1 Parameter Black and White Spots, Foreign Substances Dimension (mm) D 0.1 0.1 D 0.2 0.2 D 0.25 0.25 D 0.3 0.3 D D = ( Long + Short ) / 2 (2) Line Shape Zone X (mm) 2.0L 1.0L Y (mm) 0.03W 0.05W 0.1 W 0.1 W A * 3 3 Acceptable Number B * 3 3 In the same way (1) * : Disregard C * * * (1) Round Shape Zone A * 3 2 0 0 * : Disregard Acceptable Number B * 5 3 1 0 C * * * * * Criteria
X : Length Y : Width
Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Dimension (mm) D 0.3 0.3 D 0.4 0.4 D 0.6 0.6 D * : Disregard Total defects shall not exceed 3. Zone A * 3 2 0 Acceptable Number B * * 3 0 C * * * *
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 14/18
No. 3
Parameter The Shape of Dot (1) Dot Shape (with Dent)
0.15
Criteria
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 20.2mm
Y
(Less than 0.1mm is no counted.)
(4) Deformation
Y
(X+Y) / 20.2mm
X
Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 5 Polarizer Scratches Polarizer Dirts Not to be conspicuous defects. If the stains are removed easily from LCDP surface, the module is not defective. 6 Complex Foreign Substance Defects 7 Distance between Different Foreign Substance Defects Black spots, line shaped foreign substances or air bubbles between glass & polarizer should be 5pcs maximum in total. D0.2 : 20mm or more 0.2D : 40mm or more
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 15/18
7.Code System of Production Lot
The production lot of module is specified as follows.
Factory Number (Numeral) Factory Code (Alphabet) Production Week (15) Production Month (19, X, Y, Z) Production Year (Lower 2 digits)
8.Type Number
The type number of module is specified on the back of module as follows. Stamp Etching or Printing
9.Applying Precautions
Please contact us when questions and/or new problems not specified in this specifications arise.
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 16/18
10.Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity.
3) When the LCD module alone must be stored for long periods of time: Protect the modules from high temperature and humidity. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity.
7) For models which use CFL: High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life.
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 17/18
8) For models which use touch panels: Do not stack up modules since they can be damaged by components on neighboring modules. Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF: The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact.
10) Models which use flexible cable, heat seal, or TAB: In order to maintain reliability, do not touch or hold by the connector area. Avoid any bending, pulling, or other excessive force, which can result in broken connections.
11.Warranty
This product has been manufactured to your company's specifications as a part for use in your company's general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement.
We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company's acceptance inspection procedures. When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. We cannot accept responsibility for industrial property, which may arise through the use of your product, with exception to those issues relating directly to the structure or method of manufacturing of our product. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.
DMF-50840NFL-SFW
(AI) No.99-0076
OPTREX
OPTREX CORPORATION
Page 18/18


▲Up To Search▲   

 
Price & Availability of DMF-50840-SFW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X